In this paper, test result of two performance tests of the “Chordal Type” ultrasonic flowmeter made by Cameron inc. using NMIJ’s high Reynolds number calibration facility will be presented. This type flowmeter have been introduced to nuclear power plant in USA to MUR uprating. First test is the investigation of the effect of the inner roughness of the upstream pipe. In this test, the difference of the K-factor, which is one of correction factors of a flowmeter, between Ra = 1.7 (mm) and 14.2 (mm) is about 0.1%. To obtain the high efficiency of MUR uprating, actual flow calibration is recommended. Second test is the investigation of the relationship between “Profile Factor” and “Velocity Ratio”. As a result, the correlation obtained by calibration for many upstream conditions at Re = 3.0 × 106 can estimate “Profile Factor” at Re = 1.4 × 107 within ±0.25%. However, the correlation with Reynolds number does not behave as expected by theorem. To obtain the correction factor of flowmeter with high accuracy and reliability, the actual flow calibration under the same Reynolds number at the actual plant condition is the only effective method.
Skip Nav Destination
17th International Conference on Nuclear Engineering
July 12–16, 2009
Brussels, Belgium
Conference Sponsors:
- Nuclear Engineering Division
ISBN:
978-0-7918-4353-6
PROCEEDINGS PAPER
A Performance Test Result of Chordal Type Flowmeter Using High Reynolds Number Facility in NMIJ
Noriyuki Furuichi,
Noriyuki Furuichi
National Metrology Institute of Japan, AIST, Tsukuba, Japan
Search for other works by this author on:
Yoshiya Terao,
Yoshiya Terao
National Metrology Institute of Japan, AIST, Tsukuba, Japan
Search for other works by this author on:
Masaki Takamoto
Masaki Takamoto
National Metrology Institute of Japan, AIST, Tsukuba, Japan
Search for other works by this author on:
Noriyuki Furuichi
National Metrology Institute of Japan, AIST, Tsukuba, Japan
Yoshiya Terao
National Metrology Institute of Japan, AIST, Tsukuba, Japan
Masaki Takamoto
National Metrology Institute of Japan, AIST, Tsukuba, Japan
Paper No:
ICONE17-75140, pp. 149-155; 7 pages
Published Online:
February 25, 2010
Citation
Furuichi, N, Terao, Y, & Takamoto, M. "A Performance Test Result of Chordal Type Flowmeter Using High Reynolds Number Facility in NMIJ." Proceedings of the 17th International Conference on Nuclear Engineering. Volume 3: Thermal Hydraulics; Current Advanced Reactors: Plant Design, Construction, Workforce and Public Acceptance. Brussels, Belgium. July 12–16, 2009. pp. 149-155. ASME. https://doi.org/10.1115/ICONE17-75140
Download citation file:
2
Views
Related Proceedings Papers
Related Articles
Extrapolation and Curve-Fitting of Calibration Data for Differential Pressure Flow Meters
J. Eng. Gas Turbines Power (February,2010)
Theoretical, Numerical, and Experimental Study of the Time of Flight Flowmeter
J. Fluids Eng (April,2011)
Related Chapters
Development of a Reliability Data Handbook for Piping Components in Nordic Nuclear Power Plants (PSAM-0063)
Proceedings of the Eighth International Conference on Probabilistic Safety Assessment & Management (PSAM)
Other Components and Variations
Axial-Flow Compressors
Dynamic Behavior of Pumping Systems
Pipeline Pumping and Compression Systems: A Practical Approach