1-1 of 1
Keywords: dead zone
Close
Follow your search
Access your saved searches in your account

Would you like to receive an alert when new items match your search?
Close Modal
Sort by
Journal Articles
Article Type: Research-Article
J. Dyn. Sys., Meas., Control. July 2021, 143(7): 071005.
Paper No: DS-20-1044
Published Online: February 19, 2021
... strategy, the error of the poppet displacement is reduced from 4.9% to 2.1% by adjusting the spool displacement in the pilot stage in real-time and the flow error is reduced from 5.3% to 2.3%. The dead zone of the poppet displacement and the flow is eliminated. The hysteresis is reduced from 5.3% to 2.6...