An experimental investigation concerning tip flow field unsteadiness was performed for a high-performance, state-of-the-art transonic compressor rotor. Casing-mounted high frequency response pressure transducers were used to indicate both the ensemble averaged and time varying flow structure present in the tip region of the rotor at four different operating points at design speed. The ensemble averaged information revealed the shock structure as it evolved from a dual shock system at open throttle to an attached shock at peak efficiency to a detached orientation at near stall. Steady three-dimensional Navier Stokes analysis reveals the dominant flow structures in the tip region in support of the ensemble averaged measurements. A tip leakage vortex is evident at all operating points as regions of low static pressure and appears in the same location as the vortex found in the numerical solution. An unsteadiness parameter was calculated to quantify the unsteadiness in the tip cascade plane. In general, regions of peak unsteadiness appear near shocks and in the area interpreted as the shock-tip leakage vortex interaction. Local peaks of unsteadiness appear in mid-passage downstream of the shock-vortex interaction. Flow field features not evident in the ensemble averaged data are examined via a Navier-Stokes solution obtained at the near stall operating point.
Skip Nav Destination
Article navigation
March 1997
Research Papers
Flow Field Unsteadiness in the Tip Region of a Transonic Compressor Rotor
S. L. Puterbaugh,
S. L. Puterbaugh
Wright Laboratory, Wright-Patterson Air Force Base, OH 45433-7251
Search for other works by this author on:
W. W. Copenhaver
W. W. Copenhaver
Wright Laboratory, Wright-Patterson Air Force Base, OH 45433-7251
Search for other works by this author on:
S. L. Puterbaugh
Wright Laboratory, Wright-Patterson Air Force Base, OH 45433-7251
W. W. Copenhaver
Wright Laboratory, Wright-Patterson Air Force Base, OH 45433-7251
J. Fluids Eng. Mar 1997, 119(1): 122-128 (7 pages)
Published Online: March 1, 1997
Article history
Received:
March 29, 1994
Revised:
June 7, 1996
Online:
December 4, 2007
Citation
Puterbaugh, S. L., and Copenhaver, W. W. (March 1, 1997). "Flow Field Unsteadiness in the Tip Region of a Transonic Compressor Rotor." ASME. J. Fluids Eng. March 1997; 119(1): 122–128. https://doi.org/10.1115/1.2819097
Download citation file:
Get Email Alerts
Cited By
Related Articles
Experimental Investigation of the Effects of a Moving Shock Wave on Compressor Stator Flow
J. Turbomach (January,2007)
Influence of Flow Coefficient, Stagger Angle, and Tip Clearance on Tip Vortex in Axial Compressors
J. Fluids Eng (November,2006)
Experimental Investigation of Unsteady Flow Field in the Tip Region of an Axial Compressor Rotor Passage at Near Stall Condition With Stereoscopic Particle Image Velocimetry
J. Turbomach (July,2004)
Interaction of Rim Seal and Annulus Flows in an Axial Flow Turbine
J. Eng. Gas Turbines Power (October,2004)
Related Chapters
Outlook
Closed-Cycle Gas Turbines: Operating Experience and Future Potential
Aerodynamic Performance Analysis
Axial-Flow Compressors
Large Eddy Simulations of a Confined Tip-Leakage Cavitating Flow with Special Emphasis on Vortex Dynamics
Proceedings of the 10th International Symposium on Cavitation (CAV2018)