The effects of circumferential outlet distortion of a centrifugal pump diffuser on the impeller exit flow were investigated. A fence with sinusoidal width variation was installed at the vaneless diffuser exit. The flow field was measured at the impeller exit with and without the fence, using a hot film probe and an unsteady pressure sensor. Flow parameters varied with the circumferential position and the mean flow parameters plotted against the local flow rate at each circumferential position showed loops along the quasi-steady curves, which were obtained from the result without the fence. Simple theoretical calculations were used to predict the velocity components at the impeller exit with the relative flow angle or total pressure assumed. Good result was obtained when the relative flow angle was assumed to vary quasi-steadily, not constant with the local flow rate. The radial velocity was also reasonably predicted when the total pressure was assumed to vary quasi-steadily. A simple method is proposed to predict the impeller exit flow with downstream blockage in two-step sequence: the first step deals with the diffuser alone to obtain static pressure distribution at the diffuser inlet, while the second step deals with the impeller alone to obtain velocity components distribution at the impeller exit.

1.
Sideris
,
M. T.
, and
Van den Braembussche
,
R. A.
,
1987
, “
Influence of a Circumferential Exit Pressure Distortion on the Flow in an Impeller and Diffuser
,”
ASME J. Turbomach.
,
109
, pp.
48
54
.
2.
Fatsis
,
A.
,
Pierret
,
S.
, and
Van den Braembussche
,
R.
,
1997
, “
Three-Dimensional Unsteady Flow and Forces in Centrifugal Impellers With Circumferential Distortion of the Outlet Static Pressure
,”
ASME J. Turbomach.
,
119
, pp.
94
102
.
3.
Hagelstein, D., Van den Braembussche, R. A., Keiper, R., and Rautenberg, M., 1997, “Experimental Investigation of the Circumferential Static Pressure Distortion in Centrifugal Compressor Stages,” ASME Paper No. 97-GT-50.
4.
Sorokes, J. M., Borer, C. J., and Koch, J. M., 1998, “Investigation of the Circumferential Static Pressure Non-Uniformity Caused by a Centrifugal Compressor Discharge Volute,” ASME Paper No. 98-GT-326.
5.
Sorokes, J. M., and Koch, J. M., 2000, “The Influence of Low Solidity Vaned Diffusers on the Static Pressure Non-Uniformity Caused by a Centrifugal Compressor Discharge Volute,” ASME Paper No. 2000-GT-0454.
6.
Knapp
,
R. T.
,
1937
, “
Complete Characteristics of Centrifugal Pumps and Their Use in the Prediction of Transient Behavior
,”
Trans. ASME
,
59
, pp.
683
689
.
7.
Van den Braembussche
,
R. A.
,
Ayder
,
E.
,
Hagelstein
,
D.
,
Rautenberg
,
M.
, and
Keiper
,
R.
,
1999
, “
Improved Model for the Design and Analysis of Centrifugal Compressor Volutes
,”
ASME J. Turbomach.
,
121
, pp.
619
625
.
8.
Shim, C. Y., Hong, S. S., and Kang, S. H., 2000, “Flow Evaluations of Centrifugal Pump Impeller Using Commercial Code,” Proceedings of the Korean Fluid Machinery Association Annual Meeting, Busan, Dec. 1–2, pp. 285–292.
9.
Inoue
,
M.
, and
Cumpsty
,
N. A.
,
1984
, “
Experimental Study of Centrifugal Impeller Discharge Flow in Vaneless and Vaned Diffusers
,”
ASME J. Eng. Gas Turbines Power
,
106
, pp.
455
467
.
10.
Frigne
,
P.
, and
Van den Braembussche
,
R. A.
,
1985
, “
A Theoretical Model for Rotating Stall in the Vaneless Diffuser of a Centrifugal Compressor
,”
ASME J. Eng. Gas Turbines Power
,
107
, pp.
507
513
.
11.
Hoffmann, K. A., and Chiang, S. T., 1993, Computational Fluid Dynamics for Engineers, Engineering Education System, Wichita, Kansas.
You do not currently have access to this content.