The primary function of the ventricular chambers of the heart is to provide the proper volume of blood to the entire body that fulfills its energy requirements under a wide variety of normal and pathologic settings. If the ventricles are unable to perform this task properly, and the functions of the body deteriorates despite optimal medical management, mechanical methods are utilized to either complement or replace the pumping function of the cardiac ventricles. This presentation will describe the evolution of a non-invasive method of assisting the circulation called “counterpulsation,” and the current state of the development of an “External Left Ventricular Assist Device” (XLVAV). In this method, in the first part of the cardiac cycle, when the heart is relaxed, cardiac diastole, the device exerts a positive pressure external to the lower extremities. This increases coronary artery blood flow and cardiac output. Then when the ventricle contracts, cardiac systole, the device exerts a negative pressure, thus drawing blood away from the heart into the lower extremities, resulting in a reduction of the work and energy requirement of the left ventricle. Experimental and clinical data will be presented that describe the following successive stages of development: 1. The initial experience of Osborn in 1962 using a pressure suit and air actuation was tested in a canine model and in normal volunteers, but was not successful since sufficient pressure was not exerted on the vascular bed of the lower extremities. 2. The initial experimental experience of Birtwell and Soroff in a canine model in 1962 using water as the actuating medium. 3. The construction of a device by Birtwell with cuff-type actuators around the legs, thighs and buttocks that were inflated with water. The cuffs had rigid shells to allow pressure to be exerted to the limbs. The device was successful in increasing diastolic pressure and coronary blood flow and was used successfully in a multicenter study as an initial treatment of patients with acute myocardial infarctions. However, since the device could only apply positive pressure, it could not be used to reduce systolic pressure. 4. The device was then modified to also apply negative pressure during cardiac systole, a major step forward, and tested in a multicenter study in patients with cardiogenic shock following myocardial infacrtions with an impressive increase in the survival rate from 15% to 45%. However, the device presented logistical and patient movement problems. 5. The next evolution in the device design was the use of air to inflate the actuator cuffs. This represented a significant breakthrough, and has been successfully used in the treatment of angina pectoris by increasing coronary blood flow and the promotion or creation of collateral circulation in the myocardium. The serious shortcoming of this device is that is cannot produce negative pressure during cardiac systole, i.e., the only means of assisting the left ventricle in patients with Congestive Heart Failure. 6. The device to be described can apply negative as well as positive pressure to the lower extremities using air as the actuating medium. The device is mobile and compact, and should be effective in the treatment of patients with Congestive Heart Failure both in the hospital setting and in the home, Acute Myocardial Infarction as well as Angina Pectoris.
Skip Nav Destination
Article navigation
Design Of Medical Devices Conference Abstracts
Evolution of a Non-Invasive Method for Providing Assistance to the Heart
J. Med. Devices. Jun 2009, 3(2): 027514 (1 pages)
Published Online: July 7, 2009
Article history
Published:
July 7, 2009
Citation
Soroff, H. S., MD, and Rastegar, J. (July 7, 2009). "Evolution of a Non-Invasive Method for Providing Assistance to the Heart." ASME. J. Med. Devices. June 2009; 3(2): 027514. https://doi.org/10.1115/1.3135195
Download citation file:
613
Views
Get Email Alerts
Cited By
Related Articles
3D CAD Based Conceptual Design of a Novel Aortic Valve Stent
J. Med. Devices (June,2009)
Evaluating Design of Abdominal Aortic Aneurysm Endografts in a Patient-Specific Model Using Computational Fluid Dynamics
J. Med. Devices (June,2011)
Computational Modeling of Blood Hydrodynamics and Blockage Formation Phenomena in the Human Cardiovascular System
J. Med. Devices (June,2010)
CT Visualization of Cryoablation in Pulmonary Veins
J. Med. Devices (June,2009)
Related Chapters
Occlusion Identification and Relief within Branched Structures
Biomedical Applications of Vibration and Acoustics in Therapy, Bioeffect and Modeling
Introduction
Modified Detrended Fluctuation Analysis (mDFA)
Ultrasound-Induced Treatment of Neurodegenerative Diseases across the Blood-Brain Barrier
Biomedical Applications of Vibration and Acoustics in Therapy, Bioeffect and Modeling