Abstract

The presented work aims to compare and analyze the impact of the abrasive solution heating process using three different techniques on the etching parameters for the solid-state nuclear track detector (SSNTD) (CN-85). Water bath technique (WB) is using water as a conduction medium of heat transfer to heat the etching solution. The thermal oven technique (TO) is using air as a convection heat transfer medium to heat the etching solution. Finally, the micro-wave technique (MW) as electromagnetic radiation no need for a medium to heat the etching solution. That comparison will be achieved at different irradiation times to an Americium-241 source (241Am) of 5.486 MeV energy and 10 μCi activity as an alpha particle's emitter. Two irradiation times 10 s and 20 s are applied. Small pieces of CN-85 detectors (1 × 1) cm2 were used. CN-85 detector parameters of the etching process, with the three applying techniques (WB, TO, and MW), are estimated and compared. The obtained results from the three techniques are compared. The etching process time is developed to nearly 5 min for MW with heating by radiation mechanism compared to 25–35 min for etching techniques (WB and TO) with heating by conduction and convection mechanisms, respectively. The efficiency of MW technique with range of from 70% to 75% are five times greater than that for WB and TO techniques.

References

1.
Salim
,
M. D.
,
Marzaali
,
A. A.
,
Khalaf
,
H.
, and
Mostafa
,
M. A.
,
2023
, “
Comparison Between Etching Techniques for Solid-State Nuclear Track Detector (CN-85) to Develop Alpha Tracks
,”
Radiat. Phys. Chem.
,
213
, p.
111224
.10.1016/j.radphyschem.2023.111224
2.
Saied
,
B. M.
,
Al-Khafaji
,
R. M.
, and
Al-Bayati
,
A. T.
,
2016
, “
Measurement of Uranium Concentration in the Soil Samples by Using Solid State Nuclear Track Detectors (SSNTDs)
,”
IJSRST
,
2
(
4
), pp.
130
135
.https://ijsrst.com/home/issue/view/article.php?id=IJSRST162425
3.
Portocarrero Bonifaz
,
A.
,
Bosch Moliné
,
O.
,
Olivares Schneider
,
J.
,
La Rosa La Rosa
,
B.
,
Rojas Hancco
,
J.
,
Guevara Rojas
,
V.
,
Palacios Fernández
,
D.
,
Pereyra Anaya
,
P.
, and
López Herrera
,
M. E.
,
2020
, “
Simple and Lowcost Alternative Method for Detecting Photoneutrons Produced in Some Radiotherapy Treatments Using SSNTDs
,”
Appl. Radiat. Isotopes
,
161
, p.
109169
.10.1016/j.apradiso.2020.109169
4.
Kadhim
,
N. F.
,
Ridha
,
A. A.
,
Salim
,
M. D.
,
Hanfi
,
M. Y.
, and
Mostafa
,
M. Y. A.
,
2021
, “
Development of Alpha Tracks Measurement With Thermal Oven as an Etching Technique for SSNTDs
,”
Mater. Today: Proc.
,
44
, pp.
2903
2908
.10.1016/j.matpr.2020.12.232
5.
Al-Hamzawi
,
A. A.
,
Jaffar
,
M. S.
,
Tawfiq
,
N. F.
, and
Aswood
,
M. S.
,
2015
, “
Evaluation of Bulk Etch Rate of Solid-State Nuclear Track Detector CR-39
,”
Adv. Mater. Res.
,
1107
, pp.
712
715
.10.4028/www.scientific.net/AMR.1107.712
6.
Guo
,
S. L.
,
Chen
,
B. L.
, and
Durrani
,
S. A.
,
2020
, “
Chapter 3 - Solid-State Nuclear Track Detectors Handbook of Radioactivity Analysis
,”
Handbook of Radioactivity Analysis
,
Elsevier
, pp.
307
407
.
7.
Sajo-Bohus
,
L.
,
Vega-Carrillo
,
H. R.
, and
Virk
,
H. S.
,
2015
, “
SSNTD Technique in Photo-Neutron Applications
,”
Solid State Phenom.
,
239
, pp.
180
214
.10.4028/www.scientific.net/SSP.239.180
8.
Shoqwara
,
F.
,
Dwaikat
,
N.
, and
Saffarini
,
G.
,
2013
, “
Measurement of Radon Exhalation Rate From Building Materials
,”
Res. Rev.: J. Phys.
,
2
(
1
), pp.
10
19
.https://staff-beta.najah.edu/media/sites/default/files/Measurement_of_Radon_Exhalation_Rate_From_Building_Materials.pdf
9.
Al-Jobouri
,
H. A.
,
Rajab
,
M. Y.
, and
Najam
,
L. A.
,
2015
, “
Analysis of Nuclear Track Parameters of CN-85 Detector Irradiated to Thermal Neutrons by Using MATLAB Program
,”
Detection
,
03
(
4
), pp.
29
36
.10.4236/detection.2015.34005
10.
Bartlett
,
D. T.
,
2008
, “
100 Years of Solid State Dosimetry and Radiation Protection Dosimetry
,”
Radiat. Meas.
,
43
(
2–6
), pp.
133
138
.10.1016/j.radmeas.2007.08.004
11.
Zhou
,
D.
,
Semones
,
E.
,
O'Sullivan
,
D.
,
Zapp
,
N.
,
Weyland
,
M.
,
Reitz
,
G.
,
Berger
,
T.
, and
Benton
,
E. R.
,
2010
, “
Radiation Measured for MATROSHKA-1 Experiment With Passive Dosimeters
,”
Acta Astronaut.
,
66
(
1–2
), pp.
301
308
.10.1016/j.actaastro.2009.06.014
12.
Tripathy
,
S. P.
,
Kolekar
,
R. V.
,
Sunil
,
C.
,
Sarkar
,
P. K.
,
Dwivedi
,
K. K.
, and
Sharma
,
D. N.
,
2010
, “
Microwave-Induced Chemical Etching (MCE): A Fast-Etching Technique for the Solid Polymeric Track Detectors (SPTD)
,”
Nucl. Instrum. Methods Phys. Res. Sect. A
,
612
(
2
), pp.
421
426
.10.1016/j.nima.2009.10.096
13.
Tommasino
,
L.
,
2004
, “
Advanced Passive Detectors for Neutron Dosimetry and Spectrometry
,”
Radiat. Prot. Dosimetry
,
110
(
1–4
), pp.
183
186
.10.1093/rpd/nch167
14.
Fleischer
,
R. L.
,
Price
,
P. B.
, and
Walker
,
R. M.
,
1975
,
Nuclear Tracks in Solids: Principles and Applications
, 1st ed.,
University of California Press
, Berkeley, CA.
15.
Ilić
,
R.
, and
Durrani
,
S. A.
,
2003
, “
3 - Solid State Nuclear Track Detectors
,”
Handbook of Radioactivity Analysis
, 2nd ed., Elsevier
Academic Press
, Switzerland, pp.
179
237
.
16.
Billah
,
S. M. R.
,
2019
, “
Dielectric Polymers
,”
Functional Polymers
, Polymers and Polymeric Composites: A Reference Series,
Jafar Mazumder
,
M.
,
Sheardown
,
H.
, and
Al-Ahmed
,
A.
, eds.,
Springer
,
Cham
, pp.
241
88
.
17.
Abdel-Ghaffar
,
A. M.
,
2023
, “
Radiation Synthesis and Modification of Biopolymers and Polymeric Composites for Biomedical Applications
,”
Polym. Polym. Compos.
,
31
(1–12).10.1177/09673911231166636
18.
Sahoo
,
G. S.
,
Tripathy
,
S. P.
, and
Bandyopadhyay
,
T.
,
2014
, “
Optimization of Microwave-Induced Chemical Etching for Rapid Development of Neutron-Induced Recoil Tracks in CR-39 Detectors
,”
Nucl. Instrum. Methods Phys. Res. Sect. A
,
739
, pp.
83
88
.10.1016/j.nima.2013.12.037
19.
Nikezic
,
D.
, and
Yu
,
K. N.
,
2004
, “
Formation and Growth of Tracks in Nuclear Track Materials
,”
Mater. Sci. Eng. R: Rep.
,
46
(
3–5
), pp.
51
123
.10.1016/j.mser.2004.07.003
20.
Lidström
,
P.
,
Tierney
,
J.
,
Wathey
,
B.
, and
Westman
,
J.
,
2001
, “
Microwave Assisted Organic synthesis - A Review
,”
Tetrahedron
,
57
(
45
), pp.
9225
9283
.10.1016/S0040-4020(01)00906-1
21.
Lin
,
S. S.
,
Wu
,
C. H.
,
Sun
,
M. C.
,
Sun
,
C. M.
, and
Ho
,
Y. P.
,
2005
, “
Microwave-Assisted Enzyme-Catalyzed Reactions in Various Solvent Systems
,”
J. Am. Soc. Mass Spectrom.
,
16
(
4
), pp.
581
588
.10.1016/j.jasms.2005.01.012
22.
Al-Ta'ii
,
H. M. J.
, and
Rmadhan
,
E. J.
,
2021
, “
The Annealing Impact on Properties of CN- 85 Polymer NTD
,”
Appl. Radiat. Isot.
,
178
, p.
109933
.10.1016/j.apradiso.2021.109933
23.
Durrani
,
S. A.
, and
Bull
,
R. K.
,
1987
, “
Solid State Nuclear Track Detection Principles, Methods and Applications
,” Pergamon, Elsevier, Switzerland.
24.
Sahoo
,
G. S.
,
Tripathy
,
S. P.
,
Sharma
,
S. D.
, and
Bandyopadhyay
,
T.
,
2015
, “
Effect of Etchant Concentration on Microwave Induced Chemical Etching (MICE) of CR-39 Detector
,”
Nucl. Instrum. Methods Phys. Res., Sect. A
,
800
, pp.
51
56
.10.1016/j.nima.2015.08.019
25.
Sahoo
,
G. S.
,
Tripathy
,
S. P.
,
Roy
,
R.
,
Joshi
,
D. S.
, and
Kulkarni
,
M. S.
,
2020
, “
A New Approach for High-Dose Measurement Using CR-39 Track Detector
,”
J. Radioanal. Nucl. Chem.
,
325
(
3
), pp.
765
771
.10.1007/s10967-020-07232-3
26.
Zhang
,
Y.
,
Kong
,
X. Y.
,
Gao
,
L.
,
Tian
,
Y.
,
Wen
,
L.
, and
Jiang
,
L.
,
2015
, “
Fabrication of Nanochannels
,”
Materials
,
8
(
9
), pp.
6277
6308
.10.3390/ma8095304
27.
Saeed
,
A. D.
, and
Ilic
,
R.
,
1997
, “Radon Measurements by Etched Track Detectors,” Applications in Radiation Protection, Earth Sciences and the Environment,
World Scientific Publishing Co Pte Ltd
, Hackensack, NJ, p.
416
.10.1142/3106
28.
Kadhim
,
N. F.
, and
Jebur
,
L. A.
,
2018
, “
Investigation of the Favorable Etching Time of CN-85 Nuclear Track Detector
,”
Appl. Radiat. Isot.
,
135
, pp.
28
32
.10.1016/j.apradiso.2018.01.004
29.
Hassan
,
S. F.
,
2015
, “
Depth Determination of the Subsurface Uranium Deposits Using CR-39 Cylindrical Technique in Gneissoic Granitic Rocks, Abu Rushied Area, Southeastern Desert, Egypt
,”
J. Radiat. Res. Appl. Sci.
,
8
(
4
), pp.
562
569
.10.1016/j.jrras.2015.06.009
30.
Chavan
,
V.
,
Kalsi
,
P. C.
, and
Manchanda
,
V. K.
,
2011
, “
A Novel Room Temperature-Induced Chemical Etching (RTCE) Technique for the Enlargement of Fission Tracks in Lexan Polycarbonate SSNTD
,”
Nucl. Instrum. Methods Phys. Res., Sect. A
,
629
(
1
), pp.
145
148
.10.1016/j.nima.2010.12.020
31.
Chavan
,
V.
,
Kalsi
,
P. C.
, and
Hong
,
S.
,
2017
, “
Improved Chemical Etching of Lexan Polycarbonate Nuclear Track Detector at Low Temperature
,”
6th Asia-Pacific Symposium on Radiochemistry
, Jeju Island, Korea, Sept. 17–22, pp.
1
2
.
You do not currently have access to this content.