The radial second mode of sloshing in a circular cylindrical oil storage tank induces an out-of-plane deformation of the floating roof deck. The radial contraction of the deck due to this out-of-plane deformation contains modal components with circumferential wave numbers 0 and 2, thereby causing an elliptical deformation of the pontoon, which encloses the deck. In a previous paper, the stress caused by this elliptical deformation was analyzed by regarding the radial contraction of the deck as an enforced displacement of the whole pontoon. This paper presents an improved method for this stress analysis by considering the radial contraction of the deck as an enforced displacement of the joint between the deck and the pontoon. First, the effectiveness of the previous method in estimating the hoop membrane stress at the joint with the deck is confirmed by comparing the results obtained from the previous and improved method. Next, the improved method is used to predict also the other stress components in each portion of the pontoon. Numerical results reveal that the bending stresses are magnified locally near the joint with the deck and that the hoop membrane stress in the outer portion of the pontoon sensitively depends on the geometry of the cross-section of the pontoon. It is found that the hoop membrane stress near the joint between the outer rim and the top (or bottom) of the pontoon can be significantly reduced by increasing the slope of the top (or bottom) of the pontoon.

1.
Yamauchi
,
Y.
,
Kamei
,
A.
,
Zama
,
S.
, and
Uchida
,
Y.
, 2006, “
Seismic Design of Floating Roof of Oil Storage Tanks Under Liquid Sloshing
,”
Sloshing and Fluid Structure Vibration, ASME Pressure Vessels and Piping Division Conference
, Paper No. PVP2006-ICPVT-11-93280.
2.
Japanese Hazardous Materials Safety Techniques Association
, 2006, “
Report of Study to Develop Reasonable Modification Procedures to Satisfy Technical Standard Regarding Relatively Long Period Ground Motion for Facilities Handling Hazardous Materials
,” Report, in Japanese.
3.
Nakagawa
,
K.
, 1955, “
On the Vibration of an Elevated Water Tank-II
,”
Technol. Rep. Osaka Univ.
0030-6177,
5
, pp.
317
336
.
4.
Kondo
,
H.
, 1978, “
Free Vibration Analysis for Vertical Motion of a Floating Roof
,”
Transactions of the JSME
,
44
, pp.
1214
1223
, in Japanese.
5.
Sakai
,
F.
,
Nishimura
,
M.
, and
Ogawa
,
H.
, 1984, “
Sloshing Behavior of Floating Roof Oil Storage Tanks
,”
Comput. Struct.
0045-7949,
19
, pp.
183
192
.
6.
Sakai
,
F.
,
Inoue
,
R.
, and
Hayashi
,
S.
, 2006, “
Fluid-Elastic Analysis and Design of Sloshing in Floating-Roof Tanks Subjected to Earthquake Motions
,”
Proceedings of the ASME Pressure Vessels and Piping Division Conference
, Vancouver, BC, Canada, Paper No. PVP2006-ICPVT11-93622, pp.
1
10
.
7.
Matsui
,
T.
, 2007, “
Sloshing in a Cylindrical Liquid Storage Tank With a Floating Roof Under Seismic Excitation
,”
ASME J. Pressure Vessel Technol.
0094-9930,
129
, pp.
557
566
.
8.
Matsui
,
T.
, 2007, “
Sloshing in a Cylindrical Liquid Storage Tank With a Single-Deck Type Floating Roof Under Seismic Excitation
,”
Proceedings of the ASME Pressure Vessels and Piping Division Conference
, San Antonio, TX, Paper No. PVP2007-26249.
9.
Shimizu
,
S.
,
Naito
,
K.
, and
Koyama
,
Y.
, 1984, “
A Study on Sloshing Behaviors of Floating Roof Oil Storage Tanks During Earthquake Excited by Three-Dimensional Dynamic Simulator
,”
Ishikawajima-Harima Eng. Rev.
0578-7904,
24
, pp.
379
384
, in Japanese.
10.
Abramson
,
H. N.
,
Chu
,
W. H.
, and
Dodge
,
F. T.
, 1966, “
The Dynamic Behavior of Liquids in Moving Containers
,”
NASA
, Report No. NASA SP-106.
11.
Ibrahim
,
R. A.
,
Pilipchuk
,
V. N.
, and
Ikeda
,
T.
, 2001, “
Recent Advances in Liquid Sloshing Dynamics
,”
Appl. Mech. Rev.
0003-6900,
54
, pp.
133
199
.
12.
Bauer
,
H. F.
,
Chang
,
S. S.
, and
Wang
,
J. T. S.
, 1971, “
Nonlinear Liquid Motion in a Longitudinally Excited Container With Elastic Bottom
,”
AIAA J.
0001-1452,
9
, pp.
2333
2339
.
13.
Ibrahim
,
R. I.
, and
El-Sayad
,
M. A.
, 1999, “
Simultaneous Parametric and Internal Resonances in Systems Involving Strong Nonlinearities
,”
J. Sound Vib.
0022-460X,
225
, pp.
857
885
.
14.
Ikeda
,
T.
, and
Nakagawa
,
N.
, 1997, “
Nonlinear Vibrations of a Structure Caused by Water Sloshing in a Rectangular Tank
,”
J. Sound Vib.
0022-460X,
201
, pp.
23
41
.
15.
Ikeda
,
T.
, and
Nakagawa
,
N.
, 1995, “
Nonlinear Vibrations of a Structure Caused by Water Sloshing in a Cylindrical Tank, Fluid Structure Interaction and Structure Mechanics
,”
PVP (Am. Soc. Mech. Eng.)
0277-027X,
310
, pp.
63
76
.
16.
Peterson
,
L. D.
,
Crawley
,
E. F.
, and
Hansman
,
R. J.
, 1989, “
Nonlinear Slosh Coupled to the Dynamics of a Spacecraft
,”
AIAA J.
0001-1452,
27
, pp.
1230
1240
.
17.
Utsumi
,
M.
,
Kimura
,
K.
, and
Sakata
,
M.
, 1987, “
The Non-Stationary Random Vibration of an Elastic Circular Cylindrical Liquid Storage Tank in Simulated Earthquake Excitation (Straightforward Analysis of Tank Wall Deformation)
,”
JSME Int. J., Ser. III
0914-8825,
30
, pp.
467
475
.
18.
Utsumi
,
M.
, and
Ishida
,
K.
, 2008, “
Vibration Analysis of a Floating Roof Taking Into Account the Nonlinearity of Sloshing
,”
ASME J. Appl. Mech.
0021-8936,
75
, p.
041008
.
19.
Utsumi
,
M.
,
Ishida
,
K.
, and
Hizume
,
M.
, 2010, “
Internal Resonance of a Floating Roof Subjected to Nonlinear Sloshing
,”
ASME J. Appl. Mech.
0021-8936,
77
, p.
011016
.
20.
Miura
,
M.
, and
Kikuchi
,
T.
, 2005, “
The Sloshing Simulation of Floating Roof Tank
,”
ASME Pressure Vessels and Piping Division Conference
, Paper No. PVP2005-71439.
21.
Utsumi
,
M.
, and
Ishida
,
K.
, 2010, “
Vibration Analysis of a Floating Roof Subjected to Radial Second Mode of Sloshing
,”
ASME J. Pressure Vessel Technol.
0094-9930,
132
, p.
021303
.
You do not currently have access to this content.