The failure of receivers has been one of the main operating problems at the White Cliffs solar thermal power plant. This Technical Note reports the results of an initial investigation that identifies the cause as having been the thermal fatiguing of the tube walls. The fatigue appears to be caused by unstable heat transfer at vapor qualities below the point where critical heat flux is generally exceeded. Methods for avoiding this problem are tested.