The Laboratory Air Handling Unit (LAHU) system conditions both the office section and the laboratory section. It improves indoor air quality by maximizing outside air intake to the office section and minimizes thermal energy consumption by re-circulating the office section air to the laboratory section. This paper presents a theoretical linear optimization method and results of optimal outside air control in LAHUs. The optimal outside airflows are expressed as functions of the weather conditions (outside air temperature and enthalpy), office and laboratory airflow rates, office and laboratory supply air temperatures, and four dimensionless parameters that describe the building system and energy characteristics. The optimization method used in this paper can be used to identify the optimal control schedules in other HVAC systems.

1.
Sauer
,
H. J.
, and
Howell
,
R. H.
,
1981
, “
Promise and Potential of Air-to-Air Recovery Systems
,”
ASHRAE Trans.
,
87
, Part 1, pp.
167
182
.
2.
Barker
,
P. L.
,
1994
, “
Biomedical Laboratory Uses VAV Fume Hoods and Heat Recovery to Save Fuel Costs
,”
ASHRAE J.
,
36
(
3
), pp.
41
43
.
3.
Bard
,
E. M.
,
1994
, “
Energy Efficient HVAC System Features Thermal Storage and Heat Recovery
,”
ASHRAE J.
,
36
(
4
), pp.
38
40
.
4.
Lacey
,
D. Randall
, and
Smith
,
Darin C.
,
1997
, “
Innovative Ventilation System for Animal Anatomy Laboratory
,”
ASHRAE J.
,
39
(
4
), pp.
65
67
.
5.
Moyer
,
R. C.
,
1978
, “
Energy Recovery Performance in the Research Laboratory
,”
ASHRAE Trans.
,
84
, Part 1, pp.
538
546
.
6.
Hill
,
J. M.
, and
Jeter
,
S. M.
,
1994
, “
The Use of Heat Pipe Heat Exchangers for Enhanced Dehumidification
,”
ASHRAE Trans.
,
100
, pp.
91
102
.
7.
Neuman
,
V. A.
, and
Rousseau
,
W. H.
,
1986
, “
VAV for Laboratory Hoods—Design and Costs
,”
ASHRAE Trans.
,
92
, Part 1A, pp.
330
346
.
8.
Davis
,
S. J.
, and
Benjamin
,
R.
,
1987
, “
VAV with Fume Hood Exhaust System
,”
Heat./Piping/Air Cond.
,
59
(
8
), pp.
75
78
.
9.
Boldt
,
Jeffrey G.
,
1993
, “
Separate HVAC Systems Maximize Energy Efficiency
,”
ASHRAE J.
,
35
(
4
), pp.
16
19
.
10.
Bard
,
E. M.
,
1995
, “
Laboratory Integrates VAV Fume Hood Controls with Central Building Automation System
,”
ASHRAE J.
,
37
(
3
), pp.
40
42
.
11.
Cui, Y., and Liu, M., 2001, “Laboratory Air handling Unit System,” Proceedings of International Conference for Enhanced Building Operation, Houston. pp. 17–24.
12.
Nash, Stephen G., and Sofer, Ariela, 1996, “Linear and Nonlinear Programming,” The McGraw-Hill Companies, Inc.
13.
Degelman, L., 1986, Bin Data Weather, American Society of Heating, Refrigerating and Air-Conditioning Engineers, Inc., Atlanta.
You do not currently have access to this content.