This study presents an innovative idea to augment heat transfer to an air heater using helicoidal finned arrangement. A parametric analysis of the helicoidal shaped fin geometry is considered with helicoidal pitch ratio of 0.1666–0.3, fin diameter ratio of 1.75–2. For the placement of the fin beneath the absorber plate, longitudinal pitch ratio ranging from 0.0416 to 0.1666 are used. The flow Reynolds number used for the study ranges from 4800 to 25,000. The effects of helicoidal pitch ratio, wire diameter ratio and longitudinal pitch ratio on Nusselt number and friction factor have been discussed. It is seen from the analysis that there is a significant improvement in Nusselt number for the case of helicoidal fin of wire diameter ratio of 1 when compared to base model as well as straight fin model for the operating range of Reynolds number. It is also observed from the analysis that for the helicoidal fin configuration of helicoidal pitch ratio of 0.2333, friction factor appears to be moderate. Flow and roughness parameters for roughened solar air heater have been optimized using thermal-hydraulic enhancement factor (THEF). The study reveals that by the use of helicoidal fins, maximum enhancement in the Nusselt number is found to be 2.21 times when compared to the base model for longitudinal pitch ratio of 0.0416, helicoidal pitch ratio of 0.166 for a fixed wire diameter. The improvement obtained in performance corresponding to increased Nusselt number establishes the efficacy the helicoidal fin design for the absorber plate.

References

1.
Yadav
,
A. S.
, and
Bhagoria
,
J. L.
,
2014
, “
A CFD Based Thermo-Hydraulic Performance Analysis of an Artificially Roughened Solar Air Heater Having Equilateral Triangular Sectioned Rib Roughness on the Absorber Plate
,”
Int. J. Heat Mass Transfer
,
70
, pp.
1016
1039
.
2.
Yadav
,
A. S.
, and
Bhagoria
,
J. L.
,
2014
, “
A Numerical Investigation of Square Sectioned Transverse Rib Roughened Solar Air Heater
,”
Int. J. Therm. Sci.
,
79
, pp.
111
131
.
3.
Jin
,
D.
,
Zhang
,
M.
,
Wang
,
P.
, and
Xu
,
S.
,
2015
, “
Numerical Investigation of Heat Transfer and Fluid Flow in a Solar Air Heater Duct With Multi V-Shaped Ribs on the Absorber Plate
,”
Energy
,
89
, pp.
178
190
.
4.
Chaube
,
A.
,
Sahoo
,
P. K.
, and
Solanki
,
S. C.
,
2006
, “
Analysis of Heat Transfer Augmentation and Flow Characteristics Due to Rib Roughness Over Absorber Plate of a Solar Air Heater
,”
Renewable Energy
,
31
(
3
), pp.
317
331
.
5.
Kumar
,
S.
, and
Saini
,
R. P.
,
2009
, “
CFD Based Performance Analysis of a Solar Air Heater Duct Provided With Artificial Roughness
,”
Renewable Energy
,
34
(
5
), pp.
1285
1291
.
6.
Promvonge
,
P.
,
2010
, “
Heat Transfer and Pressure Drop in a Channel With Multiple 60° V-Baffles
,”
Int. Commun. Heat Mass Transfer
,
37
, pp.
835
840
.
7.
Karmare
,
S. V.
, and
Tikekar
,
A. N.
,
2010
, “
Analysis of Fluid Flow and Heat Transfer in a Rib Grit Roughened Surface Solar Air Heater Using CFD
,”
Sol. Energy
,
84
(
3
), pp.
409
417
.
8.
Gandhi
,
B. K.
, and
Singh
,
M. K.
,
2010
, “
Experimental and Numerical Investigations on Flow Through Wedge Shape Rib-Roughened Duct
,”
J. Inst. Eng. (India): Mech. Eng. Div.
,
90
, pp.
13
18
.https://www.ieindia.org/WebUI/IEI-Publication.aspx
9.
Yadav
,
A. S.
,
Samant
,
T. S.
, and
Varshney
,
L.
,
2015
, “
A CFD Based Analysis of Solar Air Heater Having V-Shaped Perforated Blocks on Absorber Plate
,”
Int. Res. J. Eng. Technol.
,
2
, pp.
822
829
.https://www.irjet.net/archives/V2/i2/Irjet-v2i2150.pdf
10.
Kumar
,
A.
, and
Kim
,
M.-H.
,
2016
, “
Thermal Hydraulic Performance in a Solar Air Heater Channel With Multi V-Type Perforated Baffles
,”
Energies
,
9
(
7
), p.
564
.
11.
Gawande
,
V. B.
,
Dhoble
,
A. S.
,
Zodpe
,
D. B.
, and
Chamoli
,
S.
,
2016
, “
Experimental and CFD Investigation of Convection Heat Transfer in Solar Air Heater With Reverse L-Shaped Ribs
,”
Sol. Energy
,
131
, pp.
275
295
.
12.
Deo
,
N. S.
,
Chander
,
S.
, and
Saini
,
J. S.
,
2016
, “
Performance Analysis of Solar Air Heater Duct Roughened With Multi-Gap V-Down Ribs Combined With Staggered Ribs
,”
Renewable Energy
,
91
, pp.
484
500
.
13.
Skullong
,
S.
,
Promvonge
,
P.
,
Thianpong
,
C.
, and
Pimsarn
,
N.
,
2016
, “
Thermal Performance in Solar Air Heater Channel With Combined Wavy-Groove and Perforated Delta Wing Vortex Generators
,”
Appl. Therm. Eng.
,
100
, pp.
611
620
.
14.
Alam
,
T.
, and
Kim
,
M.-H.
,
2016
, “
Numerical Study on Thermal Hydraulic Performance Improvement in Solar Air Heater Duct With Semi Ellipse Shaped Obstacles
,”
Energy
,
112
, pp.
588
598
.
15.
Gill
,
R. S.
,
Hans
,
V. S.
,
Saini
,
J. S.
, and
Singh
,
S.
,
2017
, “
Investigation on Performance Enhancement Due to Staggered Piece in a Broken Arc Rib Roughened Solar Air Heater Duct
,”
Renewable Energy
,
104
, pp.
148
162
.
16.
Omojaro
,
A. P.
, and
Aldabbagh
,
L. B. Y.
,
2010
, “
Experimental Performance of Single and Double Pass Solar Air Heater With Fins and Steel Wire Mesh as Absorber
,”
Appl. Energy
,
87
(
12
), pp.
3759
3765
.
17.
El-Sebaii
,
A. A.
,
Aboul-Enein
,
S.
,
Ramadan
,
M. R. I.
, and
El-Bialy
,
E.
,
2007
, “
Year Round Performance of Double Pass Solar Air Heater With Packed Bed
,”
Energy Convers. Manage.
,
48
(
3
), pp.
990
1003
.
18.
Priyam
,
A.
, and
Chand
,
P.
,
2016
, “
Thermal and Thermohydraulic Performance of Wavy Finned Absorber Solar Air Heater
,”
Sol. Energy
,
130
, pp.
250
259
.
19.
Manjunath
,
M. S.
,
Vasudeva Karanth
,
K.
, and
Yagnesh Sharma
,
N.
,
2017
, “
Numerical Analysis of the Influence of Spherical Turbulence Generators on Heat Transfer Enhancement of Flat Plate Solar Air Heater
,”
Energy
,
121
, pp.
616
630
.
20.
ASHRAE Standard
, 1972, “
Method of Testing to Determine the Thermal Performance of Solar Collector
,” American Society of Heating, Refrigeration and Air Conditioning Engineers, New York, pp. 93–97.
21.
Bhamjee
,
M.
,
Nurick
,
A.
, and
Madyira
,
D. M.
,
2013
, “
An Experimentally Validated Mathematical and CFD Model of a Supply Air Window: Forced and Natural Flow
,”
Energy Build.
,
57
, pp.
289
301
.
22.
Webb
,
R. L.
, and
Eckert
,
E. R. G.
,
1972
, “
Application of Rough Surface to Heat Exchanger Design
,”
Int. J. Heat Mass Transfer
,
15
(
9
), pp.
1647
1658
.
You do not currently have access to this content.