The interaction between impeller blades and diffuser vanes in a diffuser pump was investigated. Steady and unsteady pressure measurements were taken on the diffuser vanes, and the shroud wall of a vaned and a vaneless diffuser. Steady, unsteady, and ensemble-averaged unsteady data, as well as frequency spectra, are presented. The measurements were made for different flow coefficients, shaft speeds, and radial gaps between impeller blade trailing and diffuser vane leading edge (1.5 and 4.5 percent based on impeller discharge radius). The resulting lift on the vane, both steady and unsteady, was computed from the pressure measurements at midvane height. The magnitude of the fluctuating lift was found to be greater than the steady lift. The pressure fluctuations were larger on the suction side than on the pressure side attaining their maximum value, of the same order of magnitude as the total pressure rise across the pump, near the leading edge. Pressure fluctuations were also measured across the span of the vane, and those near the shroud were significantly smaller than those near the hub. The pressure fluctuations on the shroud wall itself were larger for the vaned diffuser than a vaneless diffuser. Lift, vane pressure, and shroud wall pressure fluctuations decreased strongly with increasing radial gap.
Skip Nav Destination
Article navigation
July 1989
Research Papers
Rotor–Stator Interaction in a Diffuser Pump
N. Arndt,
N. Arndt
California Institute of Technology, Pasadena, CA 91125
Search for other works by this author on:
A. J. Acosta,
A. J. Acosta
California Institute of Technology, Pasadena, CA 91125
Search for other works by this author on:
C. E. Brennen,
C. E. Brennen
California Institute of Technology, Pasadena, CA 91125
Search for other works by this author on:
T. K. Caughey
T. K. Caughey
California Institute of Technology, Pasadena, CA 91125
Search for other works by this author on:
N. Arndt
California Institute of Technology, Pasadena, CA 91125
A. J. Acosta
California Institute of Technology, Pasadena, CA 91125
C. E. Brennen
California Institute of Technology, Pasadena, CA 91125
T. K. Caughey
California Institute of Technology, Pasadena, CA 91125
J. Turbomach. Jul 1989, 111(3): 213-221 (9 pages)
Published Online: July 1, 1989
Article history
Received:
September 10, 1987
Online:
November 9, 2009
Citation
Arndt, N., Acosta, A. J., Brennen, C. E., and Caughey, T. K. (July 1, 1989). "Rotor–Stator Interaction in a Diffuser Pump." ASME. J. Turbomach. July 1989; 111(3): 213–221. https://doi.org/10.1115/1.3262258
Download citation file:
Get Email Alerts
Cited By
Related Articles
Experimental Investigation of Rotor-Stator Interaction in a Centrifugal Pump With Several Vaned Diffusers
J. Turbomach (January,1990)
Unsteady Hydrodynamic Forces due to Rotor-Stator Interaction on a Diffuser Pump With Identical Number of Vanes on the Impeller and Diffuser
J. Fluids Eng (July,2005)
Related Proceedings Papers
Related Chapters
Introduction
Mixed-flow Pumps: Modeling, Simulation, and Measurements
Other Components and Variations
Axial-Flow Compressors
Experimental Investigation of Ventilated Supercavitation Under Unsteady Conditions
Proceedings of the 10th International Symposium on Cavitation (CAV2018)