The combustor-turbine interface is an essential component in a gas turbine engine as it allows for thermal expansion between the first stage turbine vanes and combustor section. Although not considered as part of the external cooling scheme, leakage flow from the combustor-turbine interface can be utilized as coolant. This paper reports on the effects of orientation of a two-dimensional leakage slot, simulating the combustor-turbine interface, on the net heat flux reduction to a nozzle guide vane endwall. In addition to adiabatic effectiveness and heat transfer measurements, time-resolved, digital particle image velocimetry (TRDPIV) measurements were performed in the vane stagnation plane. Four interface slot orientations of 90 deg, 65 deg, 45 deg, and 30 deg located at 17% axial chord upstream of a first vane in a linear cascade were studied. Results indicate that reducing the slot angle to 45 deg can provide as much as a 137% reduction to the average heat load experienced by the endwall. Velocity measurements indicate the formation of a large leading edge vortex for coolant injected at 90 deg and 65 deg while coolant injected at 45 deg and 30 deg flows along the endwall and washes up the vane surface at the endwall junction.
Skip Nav Destination
Takasago Machinery Works,
Hyogo,
e-mail: satoshi_hada@mhi.co.jp
Article navigation
July 2013
Research-Article
Impact of the Combustor-Turbine Interface Slot Orientation on the Durability of a Nozzle Guide Vane Endwall
Karen Thole,
Karen Thole
e-mail: kthole@psu.edu
Mechanical and Nuclear Engineering Department,
Mechanical and Nuclear Engineering Department,
Pennsylvania State University
,State College, PA 16803
Search for other works by this author on:
Satoshi Hada
Takasago Machinery Works,
Hyogo,
e-mail: satoshi_hada@mhi.co.jp
Satoshi Hada
Mitsubishi Heavy Industries LTD
,Takasago Machinery Works,
Hyogo,
676-8686 Japan
e-mail: satoshi_hada@mhi.co.jp
Search for other works by this author on:
Alan Thrift
e-mail: alan.thrift@siemens.com
Karen Thole
e-mail: kthole@psu.edu
Mechanical and Nuclear Engineering Department,
Mechanical and Nuclear Engineering Department,
Pennsylvania State University
,State College, PA 16803
Satoshi Hada
Mitsubishi Heavy Industries LTD
,Takasago Machinery Works,
Hyogo,
676-8686 Japan
e-mail: satoshi_hada@mhi.co.jp
Contributed by the International Gas Turbine Institute (IGTI) of ASME for publication in the JOURNAL OF TURBOMACHINERY. Manuscript received July 16, 2012; final manuscript received August 8, 2012; published online June 5, 2013. Assoc. Editor: David Wisler.
J. Turbomach. Jul 2013, 135(4): 041019 (10 pages)
Published Online: June 5, 2013
Article history
Received:
July 16, 2012
Revision Received:
August 8, 2012
Citation
Thrift, A., Thole, K., and Hada, S. (June 5, 2013). "Impact of the Combustor-Turbine Interface Slot Orientation on the Durability of a Nozzle Guide Vane Endwall." ASME. J. Turbomach. July 2013; 135(4): 041019. https://doi.org/10.1115/1.4007602
Download citation file:
Get Email Alerts
Cited By
Related Articles
A Novel Technique for Assessing Turbine Cooling System Performance
J. Turbomach (July,2011)
Experimental Study of the Endwall Heat Transfer of a Transonic Nozzle Guide Vane With Upstream Jet Purge Cooling Part 2—Effect of Combustor-Nozzle Guide Vane Misalignment
J. Turbomach (May,2022)
Film Cooling From a Row of Holes Supplemented With Antivortex Holes
J. Turbomach (April,2009)
The
Effects of Combustor Cooling Features on Nozzle Guide Vane Film Cooling
Experiments
J. Turbomach (January,2019)
Related Proceedings Papers
Related Chapters
Outlook
Closed-Cycle Gas Turbines: Operating Experience and Future Potential
Cavitating Structures at Inception in Turbulent Shear Flow
Proceedings of the 10th International Symposium on Cavitation (CAV2018)
Re-entrant Gas Flows of High-speed Ventilated Supercavity
Proceedings of the 10th International Symposium on Cavitation (CAV2018)